INFORMATION HUB

This short procedure reuses existing service step pages. Edit the referenced step pages to update this procedure everywhere.

WARNING

Read Safety instructions before starting.

  • Remove the kill switch before starting any service procedure to prevent accidental motor start.
  • Disconnect the battery before starting any work on the interface.
  • Wear nitrile gloves when handling silicone/adhesive and when handling the interface during and after degreasing.
  • Do not cut deeper than 2-3 mm when cutting silicone around the interface. Use only plastic tools on the sealing surface.

Required tools

Required parts and consumables

Disassembly

IB-DIS-001 DISASSEMBLY STEP 1 - Cut silicone around interface

Tools:

Removing parts:

  • No parts removed in this step.

Procedure:

  1. Place the transom bracket and outboard on a stable holder.
  2. Cut under the interface to a depth of 2-3 mm around the interface edge.

CAUTION

Do not cut deeper than required. Cutting too deep can damage the interface, cables or sealing surface.

Link to original

IB-DIS-002 DISASSEMBLY STEP 2 - Remove charging connector

Tools:

Removing parts:

  • No parts removed in this step.

Procedure:

  1. Unscrew the two screws on the charging connector cap.
  2. Pull the charging connector cap out of the housing.
  3. The connector has a locking tab โ€” use the tool to unlock the connector.
  4. Remove the charging connector.
Link to original

IB-DIS-003 DISASSEMBLY STEP 3 - Screw in interface removal tool

Tools:

Removing parts:

  • No parts removed in this step.

Procedure:

  1. Screw the interface removal tool (900040006) into the mounting holes next to the charging connector socket.
Link to original

IB-DIS-004 DISASSEMBLY STEP 4 - Loosen interface

Tools:

Removing parts:

  • No parts removed in this step.

Procedure:

  1. Set the heat gun to 350ยฐC and heat around the interface joint to soften the silicone.
  2. Move the interface removal tool left, right, up and down until the interface breaks free from the silicone.

CAUTION

Use only a plastic tool on the sealing surface. Metal tools can scratch the housing and cause leakage after assembly.

NOTE

The interface is not reusable once removed and must be replaced โ€” see IB-DIS-005 DISASSEMBLY STEP 5 - Lift interface.

Link to original

IB-DIS-005 DISASSEMBLY STEP 5 - Lift interface

Tools:

  • No tools required.

Removing parts:

Procedure:

  1. When the silicone is loosened, lift the interface by hand.
  2. Lift only far enough to access the connectors.

CAUTION

Do not pull the interface away from the housing before all connectors are disconnected.

Link to original

IB-DIS-006 DISASSEMBLY STEP 6 - Disconnect interface connectors

Tools:

  • No tools required.

Removing parts:

  • No parts removed in this step.

Procedure:

  1. Carefully disconnect the connectors shown in the picture.
  2. Some connectors have a small locking tab โ€” release it before pulling the connector apart.
  3. Support the connector bodies during removal. Do not pull on the wires.
Link to original

Check

IB-CHK-001 CHECK STEP 1 - Inspect removed interface and connectors

Tools:

  • No tools required.

Procedure:

  1. Inspect the motor housing sealing surface for residual silicone, cuts, scratches or other damage. Re-clean if needed before reassembly.
  2. Inspect the interface connectors and signal/charge cables for corrosion, damage or bent pins.
  3. Inspect the Bungie cord used to secure the interface during silicone curing (see IB-ASM-009 ASSEMBLY STEP 9 - Attach first bungee cord point) and its mounting points for wear, cracking or damage.

CAUTION

๐Ÿ—‘ Do not reuse the removed Interface assembly GO (120020002) / Interface assembly DE2 (120020003) (select the correct variant for the unit). Cutting the silicone seal during removal compromises its watertight seal โ€” always install a new interface assembly.

TODO

Add a dedicated photo showing the sealing surface and connectors being inspected, separate from the disassembly/reassembly action photos.
Define acceptance criteria for cable/connector wear (e.g. corrosion limits, pin damage tolerance, minimum bungee cord condition).

Link to original

TODO

Add the approved button harness inspection criteria, connector identification and replacement method. The current source manuals do not contain a dedicated button harness replacement step.

Reassembly

IB-ASM-008 ASSEMBLY STEP 8 - Connect interface cables

Tools:

Consumables:

Installing parts:

Procedure:

  1. Plug in the signal cable connectors. The connectors are keyed and cannot be mismatched.
  2. Plug in the charge connector.
  3. Ensure all connector lock tabs are fully engaged.
  4. Apply a small amount of silicone to the back of the signal connectors.

CAUTION

Do not apply silicone to connector contact surfaces.

Link to original

IB-ASM-009 ASSEMBLY STEP 9 - Attach first bungee cord point

Tools:

Installing parts:

  • No parts installed in this step.

Procedure:

  1. Attach one side of the bungee cord to the tiller bolts.
  2. Keep the bungee cord ready for holding the interface after silicone application.
Link to original

IB-ASM-010 ASSEMBLY STEP 10 - Clean sealing surfaces

Tools:

  • No tools required.

Consumables:

Procedure:

  1. Clean the sealing surface of the interface with isopropanol.
  2. Clean the sealing surface of the motor housing with isopropanol.
  3. Make sure both surfaces are dry before applying silicone.

CAUTION

Silicone must be applied only to clean and dry sealing surfaces.

Link to original

IB-ASM-011 ASSEMBLY STEP 11 - Apply silicone to interface

Tools:

Consumables:

Procedure:

  1. Apply a continuous bead of silicone to the interface sealing surface.
  2. Make sure the silicone is applied around the full sealing perimeter.
  3. Avoid gaps in the silicone bead.

CAUTION

Missing silicone on the sealing perimeter can cause leakage.

Link to original

IB-ASM-012 ASSEMBLY STEP 12 - Spread silicone on sealing surface

Tools:

  • No tools required.

Consumables:

  • Rubber gloves

Procedure:

  1. Put on rubber gloves.
  2. Spread the applied silicone evenly around the mating surface with a gloved finger.
  3. Keep the silicone layer continuous around the full perimeter.
Link to original

IB-ASM-013 ASSEMBLY STEP 13 - Install interface

Tools:

  • No tools required.

Installing parts:

Procedure:

  1. Position the interface on the motor housing.
  2. Press the interface down firmly.
  3. Hold the interface in position until it is secured with the bungee cords.
  4. Check that a small amount of silicone squeezes out around the edge.

CAUTION

If no silicone squeezes out, remove the interface, clean the sealing surfaces and repeat the sealing procedure from assembly step 10.

Link to original

IB-ASM-014 ASSEMBLY STEP 14 - Remove excess silicone

Tools:

Procedure:

  1. Scrape away excess silicone with the silicone squeegee.
  2. Do not disturb the interface position while removing excess silicone.
Link to original

IB-ASM-015 ASSEMBLY STEP 15 - Secure interface with bungee cords

Tools:

Procedure:

  1. Attach the bungee cords over the interface.
  2. Apply as much tension as possible without shifting the interface.
  3. Route the first bungee cord between the charging socket and screw.
  4. Route the second bungee cord over the kill switch surface.

CAUTION

Make sure the bungee cords hold the interface evenly against the housing during curing.

Link to original

IB-ASM-016 ASSEMBLY STEP 16 - Check bungee cord position

Tools:

  • No tools required.

Procedure:

  1. Check that the first bungee cord is routed between the charging socket and screw.
  2. Check that the second bungee cord is routed over the kill switch surface.
  3. Verify that the interface is still fully seated.
Link to original

IB-ASM-017 ASSEMBLY STEP 17 - Final silicone cleanup and curing

Tools:

Consumables:

  • Paper towel
  • Mild window cleaner

Procedure:

  1. Wipe away any remaining silicone from the outboard.
  2. Take extra care in the areas directly below the bungee cords.
  3. Leave the assembly to cure for at least 48 h at room temperature.
  4. After curing, scrape away any remaining silicone.
  5. Clean the interface with a cloth and mild window cleaner for the final finish.

CAUTION

Do not remove the bungee cords or move the interface before the silicone has cured.

Link to original

Color key

Blue = Disassembly ยท Red = Check ยท Green = Reassembly