This short procedure reuses existing service step pages. Edit the referenced step pages to update this procedure everywhere.
WARNING
Read Safety instructions before starting.
- Remove the kill switch before starting any service procedure to prevent accidental motor start.
- Disconnect the battery before starting any work on the interface.
- Wear nitrile gloves when handling silicone/adhesive and when handling the interface during and after degreasing.
- Do not cut deeper than 2-3 mm when cutting silicone around the interface. Use only plastic tools on the sealing surface.
Required tools
- Exacto knife
- Interface Removal Tool Go & DE2 ALU (900040008)
- tool_for_connector_deatached (250020001)
- Heat gun
- Bungie cord
- Silicone dispenser
- Silicone Squeegee
Required parts and consumables
- ๐ Interface assembly GO (120020002) / Interface assembly DE2 (120020003) (select the correct variant for the unit) โ the removed interface must not be reused
- Isopropanol
- Silicone Dowsil 7091 (010010001)
- Rubber gloves
Disassembly
IB-DIS-001 DISASSEMBLY STEP 1 - Cut silicone around interface
Tools:
Removing parts:
- No parts removed in this step.
Procedure:
- Place the transom bracket and outboard on a stable holder.
- Cut under the interface to a depth of 2-3 mm around the interface edge.
Link to originalCAUTION
Do not cut deeper than required. Cutting too deep can damage the interface, cables or sealing surface.
IB-DIS-002 DISASSEMBLY STEP 2 - Remove charging connector
Tools:
Removing parts:
- No parts removed in this step.
Procedure:
Link to original
- Unscrew the two screws on the charging connector cap.
- Pull the charging connector cap out of the housing.
- The connector has a locking tab โ use the tool to unlock the connector.
- Remove the charging connector.
IB-DIS-003 DISASSEMBLY STEP 3 - Screw in interface removal tool
Tools:
Removing parts:
- No parts removed in this step.
Procedure:
Link to original
- Screw the interface removal tool (900040006) into the mounting holes next to the charging connector socket.
IB-DIS-004 DISASSEMBLY STEP 4 - Loosen interface
Tools:
Removing parts:
- No parts removed in this step.
Procedure:
- Set the heat gun to 350ยฐC and heat around the interface joint to soften the silicone.
- Move the interface removal tool left, right, up and down until the interface breaks free from the silicone.
CAUTION
Use only a plastic tool on the sealing surface. Metal tools can scratch the housing and cause leakage after assembly.
Link to originalNOTE
The interface is not reusable once removed and must be replaced โ see IB-DIS-005 DISASSEMBLY STEP 5 - Lift interface.
IB-DIS-005 DISASSEMBLY STEP 5 - Lift interface
Tools:
- No tools required.
Removing parts:
- ๐ Interface assembly GO (120020002) / Interface assembly DE2 (120020003) (select the correct variant for the unit) (not reusable โ discard after removal)
Procedure:
- When the silicone is loosened, lift the interface by hand.
- Lift only far enough to access the connectors.
Link to originalCAUTION
Do not pull the interface away from the housing before all connectors are disconnected.
IB-DIS-006 DISASSEMBLY STEP 6 - Disconnect interface connectors
Tools:
- No tools required.
Removing parts:
- No parts removed in this step.
Procedure:
Link to original
- Carefully disconnect the connectors shown in the picture.
- Some connectors have a small locking tab โ release it before pulling the connector apart.
- Support the connector bodies during removal. Do not pull on the wires.
IB-DIS-007 DISASSEMBLY STEP 7 - Disconnect signal cable
Tools:
- Exacto knife, if silicone is present
Removing parts:
- No parts removed in this step.
Procedure:
- Press the small latch on the side of the connector.
- Disconnect the smaller signal cable.
- If the connector is covered with silicone, carefully remove only the excess silicone needed to release the latch.
Link to originalCAUTION
Do not cut into the connector housing or cable insulation when removing silicone.
Check
IB-CHK-001 CHECK STEP 1 - Inspect removed interface and connectors
Tools:
- No tools required.
Procedure:
- Inspect the motor housing sealing surface for residual silicone, cuts, scratches or other damage. Re-clean if needed before reassembly.
- Inspect the interface connectors and signal/charge cables for corrosion, damage or bent pins.
- Inspect the Bungie cord used to secure the interface during silicone curing (see IB-ASM-009 ASSEMBLY STEP 9 - Attach first bungee cord point) and its mounting points for wear, cracking or damage.
CAUTION
๐ Do not reuse the removed Interface assembly GO (120020002) / Interface assembly DE2 (120020003) (select the correct variant for the unit). Cutting the silicone seal during removal compromises its watertight seal โ always install a new interface assembly.
Link to originalTODO
Add a dedicated photo showing the sealing surface and connectors being inspected, separate from the disassembly/reassembly action photos.
Define acceptance criteria for cable/connector wear (e.g. corrosion limits, pin damage tolerance, minimum bungee cord condition).TODO
Add the approved battery signal cable inspection criteria, connector identification and replacement method. The current source manuals do not contain a dedicated battery signal cable replacement step.
Reassembly
IB-ASM-008 ASSEMBLY STEP 8 - Connect interface cables
Tools:
Consumables:
Installing parts:
- Interface assembly GO (120020002) / Interface assembly DE2 (120020003) (select the correct variant for the unit)
Procedure:
- Plug in the signal cable connectors. The connectors are keyed and cannot be mismatched.
- Plug in the charge connector.
- Ensure all connector lock tabs are fully engaged.
- Apply a small amount of silicone to the back of the signal connectors.
Link to originalCAUTION
Do not apply silicone to connector contact surfaces.
IB-ASM-009 ASSEMBLY STEP 9 - Attach first bungee cord point
Tools:
Installing parts:
- No parts installed in this step.
Procedure:
Link to original
- Attach one side of the bungee cord to the tiller bolts.
- Keep the bungee cord ready for holding the interface after silicone application.
IB-ASM-010 ASSEMBLY STEP 10 - Clean sealing surfaces
Tools:
- No tools required.
Consumables:
Procedure:
- Clean the sealing surface of the interface with isopropanol.
- Clean the sealing surface of the motor housing with isopropanol.
- Make sure both surfaces are dry before applying silicone.
Link to originalCAUTION
Silicone must be applied only to clean and dry sealing surfaces.
IB-ASM-011 ASSEMBLY STEP 11 - Apply silicone to interface
Tools:
Consumables:
Procedure:
- Apply a continuous bead of silicone to the interface sealing surface.
- Make sure the silicone is applied around the full sealing perimeter.
- Avoid gaps in the silicone bead.
Link to originalCAUTION
Missing silicone on the sealing perimeter can cause leakage.
IB-ASM-012 ASSEMBLY STEP 12 - Spread silicone on sealing surface
Tools:
- No tools required.
Consumables:
- Rubber gloves
Procedure:
Link to original
- Put on rubber gloves.
- Spread the applied silicone evenly around the mating surface with a gloved finger.
- Keep the silicone layer continuous around the full perimeter.
IB-ASM-013 ASSEMBLY STEP 13 - Install interface
Tools:
- No tools required.
Installing parts:
- Interface assembly GO (120020002) / Interface assembly DE2 (120020003) (select the correct variant for the unit)
Procedure:
- Position the interface on the motor housing.
- Press the interface down firmly.
- Hold the interface in position until it is secured with the bungee cords.
- Check that a small amount of silicone squeezes out around the edge.
Link to originalCAUTION
If no silicone squeezes out, remove the interface, clean the sealing surfaces and repeat the sealing procedure from assembly step 10.
IB-ASM-014 ASSEMBLY STEP 14 - Remove excess silicone
Tools:
Procedure:
Link to original
- Scrape away excess silicone with the silicone squeegee.
- Do not disturb the interface position while removing excess silicone.
IB-ASM-015 ASSEMBLY STEP 15 - Secure interface with bungee cords
Tools:
Procedure:
- Attach the bungee cords over the interface.
- Apply as much tension as possible without shifting the interface.
- Route the first bungee cord between the charging socket and screw.
- Route the second bungee cord over the kill switch surface.
Link to originalCAUTION
Make sure the bungee cords hold the interface evenly against the housing during curing.
IB-ASM-016 ASSEMBLY STEP 16 - Check bungee cord position
Tools:
- No tools required.
Procedure:
Link to original
- Check that the first bungee cord is routed between the charging socket and screw.
- Check that the second bungee cord is routed over the kill switch surface.
- Verify that the interface is still fully seated.
IB-ASM-017 ASSEMBLY STEP 17 - Final silicone cleanup and curing
Tools:
Consumables:
- Paper towel
- Mild window cleaner
Procedure:
- Wipe away any remaining silicone from the outboard.
- Take extra care in the areas directly below the bungee cords.
- Leave the assembly to cure for at least 48 h at room temperature.
- After curing, scrape away any remaining silicone.
- Clean the interface with a cloth and mild window cleaner for the final finish.
Link to originalCAUTION
Do not remove the bungee cords or move the interface before the silicone has cured.
Color key